ผู้ผลิตระบบคลีนรูมตั้งแต่ปี 2005

产品
ผลิตภัณฑ์
หน้าหลัก/ Cleanroom Booth/ Clean Panel Clean Booth / Hardwall Modular Clean Booth

Clean Panel Clean Booth / Hardwall Modular Clean Booth

WONCLEAN's hardwall modular clean booth uses cleanroom sandwich panels to define a dedicated production or inspection area. Plan the enclosure, access, filtration and utility connections around your workflow, with the cleanliness target and acceptance tests specified for your project.

รายละเอียดผลิตภัณฑ์

Hardwall Clean Booth for a Dedicated Process Area

A clean panel clean booth creates a defined workspace within a larger production facility. Built with rigid cleanroom sandwich panels, it suits projects that need a durable enclosure with planned doors, equipment openings and utility connections. WONCLEAN helps you match the layout to the process, the available floor space and the surrounding environment.

This hardwall modular clean booth is a practical option for an established workstation or production cell where a consistent enclosure layout matters. Specify the airflow and filtration alongside the walls so the complete system supports your contamination control requirements.

Why Choose a Clean Panel Enclosure?

  • Defined working boundaries: Rigid walls separate the process area from nearby activity and provide fixed locations for access and equipment interfaces.
  • Cleanable interior surfaces: Smooth panel faces support routine cleaning. Select the surface finish and cleaning agents together to suit your operating procedure.
  • Planned panel joints: Joint details, doors and service penetrations can be coordinated as part of the enclosure design, supporting the intended airflow arrangement.
  • Panel-based construction: A modular layout allows future changes to be considered at the design stage. Expansion or relocation depends on the structure, services and installation conditions.

Configuration to Confirm Before Ordering

Hardwall clean booth project requirements
ItemWhat to specify
Enclosure dimensionsRequired internal working area, clear height and external space limits.
Panel systemPanel thickness, core, surface finish and joint details for the intended use.
Airflow and filtrationTarget cleanliness, FFU and filter requirements, air return paths and any pressure requirements.
Access and observationDoor locations, opening sizes, viewing needs and personnel or material routes.
Equipment and utilitiesEquipment footprint, heat load, maintenance clearance and required service penetrations.
Site and acceptanceFloor condition, electrical supply, installation access and agreed commissioning tests.

Plan the Booth Around Your Workflow

Consider a hardwall enclosure for precision assembly, inspection or equipment work where airborne particles are a process concern. Start with the equipment layout, then map how operators, components and finished items enter and leave. Include enough space for maintenance and cleaning without obstructing airflow.

Share the surrounding room conditions and any temperature or humidity requirements. These need to be addressed in the environmental design; insulated panels alone do not establish controlled operating conditions.

Frequently Asked Questions

Does a hardwall clean booth automatically meet an ISO class?

No. Specify the required cleanliness class and operating state when requesting a quotation. Performance depends on filtration, airflow, leakage paths, surrounding conditions and use, and must be verified by testing the installed enclosure.

Which panel thickness or core should I choose?

Choose the panel specification around the enclosure size, structural needs, cleaning routine and environmental requirements. If fire performance is required, confirm the applicable assembly specification and supporting documentation before ordering.

Can the booth accommodate existing equipment?

Provide equipment drawings, service connections, heat output and maintenance clearances. These details help determine the booth dimensions, installation sequence, openings and utility routing.

Can the booth be expanded or moved later?

Future changes should be discussed during design. Feasibility depends on the panel arrangement, supporting structure, available space and services; modifications may also require airflow adjustment and renewed performance testing.

Compare Other Clean Booth Materials

For a transparent enclosure with direct process visibility, explore the acrylic clean booth. For flexible strip-curtain access, see the anti-static PVC clean booth.

Request a Hardwall Clean Booth Quotation

Send your layout, working dimensions, equipment details, target cleanliness and installation location. Include access, utility and cleaning requirements so WONCLEAN can review the configuration. Send your project requirements.

แท็กยอดนิยม: Clean Boothcleanroom booth

ฝากข้อความ

หากต้องการรายละเอียดผลิตภัณฑ์หรือข้อมูลสินค้าใหม่ โปรดฝากข้อความ เราจะตอบกลับโดยเร็ว

หากมีคำถามหรือข้อเสนอแนะ โปรดฝากข้อความไว้ เราจะตอบกลับโดยเร็วที่สุด